Description
Altronix T3VK75F20 20-Door Altronix/HID VertX® Access and Power Integration Kit
Part Number: T3VK75F20 |
Manufacturer: Altronix |
Description
Buy The Altronix T3VK75F20 From ACR Security at a Discounted Price, In Stock, Ships Today
20-Door Altronix/HID VertX® Access and Power Integration Kit - Trove3V3 with eFlow104NB, eFlow102NB, (2) ACM8, ACM4, PD8UL, RSB2
-
eFlow104NB Power Supply/Charger - 1
-
Input
- Voltage: 120VAC, 60Hz, 4.5A max.
- Main Fuse: 6.5A / 250V.
-
Output
- Voltage: 24VDC.
- Current: 10A continuous.
-
-
eFlow102NB Power Supply/Charger - 2
-
Input
- Voltage: 120VAC, 60Hz, 3.5A max.
- Main Fuse: 5A / 250V.
-
Output
- Voltage: 12VDC.
- Current: 10A continuous.
-
-
Both Power Supplies
-
Outputs
- Auxiliary: Class 2 power-limited @ 1A (unswitched).
- Other: Overvoltage protection. Filtered and regulated.
-
Battery Backup (not included)
- Type: Sealed lead acid or gel type.
- Fuse Rating: 10A / 32VDC.
- Failover: Upon AC loss, instantaneous.
-
Fire Alarm Disconnect
- Supervised: Latching or non-latching.
- EOL: 10K Resistor.
-
Supervision
- AC Failure: Form C contacts.
- Battery: Form C contacts.
- Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units or 71-73% for 12V units. Prevents deep battery discharge.
-
Indicators (LED)
- AC Input: 120VAC is present.
- DC Output: Powered.
-
-
Two (2) ACM8 Access Power Controllers
-
Input
- Voltage: 24VDC from eFlow104NB.
- Main Fuse: 10A / 250V.
-
Outputs
- Voltage: 24VDC.
- Eight (8) independently controlled fused outputs:
- a) Fail-Safe and/or Fail-Secure power outputs. Form C Relays rated 28VAC or VDC @ 2.5A.
- b) Auxiliary power outputs (unswitched).
- c) Any combination of the above.
- Output Fuses: 3.5A / 250V.
-
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized).
- Green LED FACP disconnect is triggered.
-
-
ACM4 Access Power Controller
-
Input
- Voltage: 24VDC from eFlow104NB.
- Main Fuse: 10A / 32V.
-
Outputs
- Voltage: 24VDC.
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
- b) Four (4) dry form C 5A rated relay outputs.
- c) Any combination of the above.
- Four (4) auxiliary power outputs (unswitched).
- Output Fuses: 3A / 32V.
-
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized).
- Green LED: FACP disconnect is triggered.
-
-
PD8UL Power Distribution Module
-
Input
- Voltage: 12VDC from eFlow102NB.
-
Outputs
- Voltage: 12VDC.
- Eight (8) fuse protected outputs. 3.5A per output max.
- Output Fuses: 3.5A / 250V.
-
Indicators (LED)
- Green LED: DC Output.
-