Altronix T1MK1F4SD TROVE1M1 4DR ALTRONIX/MERC KIT

Part Number: T1MK1F4SD
Manufacturer: Altronix

Description
Buy The Altronix T1MK1F4SD From ACR Security at a Discounted Price, In Stock, Ships Today

Altronix T1MK1F4SD TROVE1M1 4DR ALTRONIX/MERC KIT

  • eFlow4NB Power Supply/Charger
    • Input
      • Voltage: 120VAC, 60Hz.
      • Fusing: 5A / 250V.
    • Output
      • Voltage: 24VDC.
      • Current: 4A continuous.
      • Other: Overvoltage protection. Filtered and regulated.
  • Battery Backup
    • Capacity: 7AH / 12VDC (Up to 2 within enclosure). 40 AH / 65 AH (requires separate enclosure).
    • Type: Sealed lead acid or gel type.
    • Fuse: Rating 7.5A/32V.
    • Failover: Upon AC loss, instantaneous.
  • Supervision
    • AC Failure: Form C contacts.
    • Battery: Form C contacts.
    • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
  • Indicators LED
    • Input: 120VAC is present.
    • DC Output: Powered.
    • Battery: Discharged or not connected.
  • VR6 Voltage Regulator
    • Input
      • Voltage: 24VDC from eFlow4NB.
    • Output
      • Voltage: 12VDC.
      • Current: 6A continuous.
      • Other: Surge suppression.
    • Indicators (LED)
      • Input: 24VDC is present.
      • Output: Powered.
  • ACM4CB Access Power Controller
    • Input
      • Voltage: 24VDC from eFlow4NB.
      • Fusing: 10A / 32V.
    • Output
      • Voltage: 24VDC.
      • Four (4) independently controlled 2.5A outputs:
      • a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
      • b) Any combination of the above.
      • Four (4) auxiliary power outputs (unswitched).
    • Outputs Ratings
      • PTCs: 2.5A.
    • Indicators (LED)
      • Red LEDs: Outputs are triggered (relays energized).
      • Green LED: FACP disconnect is triggered.
  • PDS8CB Dual Input Power Distribution Module
    • Input
      • Voltage: 12VDC from VR6 and 24VDC from eFlow4NB.
      • Input PTC: 9A.
    • Output
      • Voltage: 12VDC and/or 24VDC.
      • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
      • Individual outputs may be set to OFF position for servicing.
    • Outputs Ratings
      • PTCs: 2.5A.
    • Indicators (LED)
      • DC Output: Eight (8) individual output LEDs.
      • Green: 12VDC
      • Red: 24VDC.